View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code with webserver privileges. The following versions of Danfoss AK-SM 8xxA Series are affected: AK-SM8xxA <=5.4.0 (CVE-2026-129713) CVSS Vendor Equipment v3 9.8 Danfoss AK-SM8xxA 1 Vulnerability Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Faciliti...
Details
Source publication: CISA Cyber Advisories
Feed URL: https://www.cisa.gov/cybersecurity-advisories/all.xml
Link: https://www.cisa.gov/news-events/ics-advisories/icsa-26-328-03
Published: 2026-11-24T12:00:00+00:00
Related on this site
Software flaws named here
- CVE-2026-129713: Danfoss AK-SM8xxASeverity 9.3, critical2% chance of attack in 30 days
Stack-based buffer overflow in Danfoss AK-SM8xxA unauthenticated CGI handler
A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows remote attackers to send specially crafted HTTP/S POST requests, leading to memory corruption, webserver restart and hypothetically potential arbitrary code execution with webserver privileges. Authentication is not required to exploit this vulnerability.
What to do about it
- Find out whether you run the affected product. Check the product names and versions above against what your business uses, including firewalls, routers, plugins and servers your provider manages for you.
- Apply the vendor’s fix, or the workaround. Install the update from the product’s maker. If none exists yet, follow their temporary workaround or take the affected system off the public internet.
- Check for signs it was already used. Look for new admin accounts, unexpected files and unusual outgoing traffic. If the flaw is on the CISA exploited list, assume attackers have already tried it on exposed systems.
Where this came from and what it does not tell you
- Source type
- News feed excerpt. The headline and opening summary from the publisher’s own feed. We do not copy the article.
- First seen by Securlabs
- ; last updated
- Limits
- Our summary is only what the publisher put in its feed. The full story, with quotes and later corrections, is at the source.
View the raw record (JSON)
{
"id": "news_3a8ad132bbb8c2a0",
"title": "Danfoss AK-SM 8xxA Series",
"category": "cve",
"severity": "critical",
"status": "active",
"entity": "Cyber Incident",
"country_code": "US",
"summary": "View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code with webserver privileges. The following versions of Danfoss AK-SM 8xxA Series are affected: AK-SM8xxA <=5.4.0 (CVE-2026-129713) CVSS Vendor Equipment v3 9.8 Danfoss AK-SM8xxA 1 Vulnerability Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Commercial Faciliti...",
"technical_details": "Source publication: CISA Cyber Advisories\nFeed URL: https://www.cisa.gov/cybersecurity-advisories/all.xml\nLink: https://www.cisa.gov/news-events/ics-advisories/icsa-26-328-03\nPublished: 2026-11-24T12:00:00+00:00",
"source_name": "CISA Cyber Advisories",
"source_url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-328-03",
"raw_data": "{\"tags\": [], \"author\": \"CISA\", \"guid\": \"/node/25842\"}",
"detected_at": "2026-11-24T12:00:00+00:00",
"resolved_at": null,
"updated_at": "2026-11-27T17:44:49.950403+00:00",
"image_url": null
}