CISA Adds 10 Known Exploited Vulnerabilities to Catalog
- About
- Cyber Incident
- Detected
CISA has added 10 new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog , based on evidence of active exploitation. CVE-2023-25914 Danfoss AK-SM 800A Series Path Traversal Vulnerability CVE-2023-25915 Danfoss AK-SM 800A Series Improper Input Validation Vulnerability CVE-2025-41450 Danfoss AK-SM 800A Series Improper Authentication Vulnerability CVE-2026-103406 Hewlett Packard ...
Details
Source publication: CISA Cyber Advisories
Feed URL: https://www.cisa.gov/cybersecurity-advisories/all.xml
Link: https://www.cisa.gov/news-events/alerts/2026/11/25/cisa-adds-10-known-exploited-vulnerabilities-catalog
Published: 2026-11-25T12:00:00+00:00
Related on this site
Software flaws named here
- CVE-2023-25914: Danfoss AK-SM 800A SeriesExploited in the wildSeverity 8.8, high2% chance of attack in 30 days
Danfoss AK-SM 800A Series Path Traversal Vulnerability
Danfoss AK-SM 800A Series contains a path traversal vulnerability that could allow an attacker to access and read underlying server system files via the XML interface.
US federal agencies had to fix it by 2026-11-28.
- CVE-2023-25915: Danfoss AK-SM 800A SeriesExploited in the wildSeverity 8.8, high2% chance of attack in 30 days
Danfoss AK-SM 800A Series Improper Input Validation Vulnerability
Danfoss AK-SM 800A Series contains an improper input validation vulnerability that could allow a remote attacker to run arbitrary commands on the affected system.
US federal agencies had to fix it by 2026-11-28.
- CVE-2025-41450: Danfoss AK-SM 800A SeriesExploited in the wildSeverity 7.5, high4% chance of attack in 30 days
Danfoss AK-SM 800A Series Improper Authentication Vulnerability
Danfoss AK-SM 800A Series contains an improper authentication vulnerability that could allow an attacker to generate a web report exposing sensitive information, including internal IP addresses, usernames, and store names.
US federal agencies had to fix it by 2026-12-09.
- CVE-2026-103406: Hewlett Packard Enterprise (HPE) Juniper Session Smart Conductor and Session Smart RouterExploited in the wildSeverity 9.8, critical2% chance of attack in 30 days
Hewlett Packard Enterprise (HPE) Juniper Session Smart Conductor and Session Smart Router OS Command Injection Vulnerability
Hewlett Packard Enterprise (HPE) Juniper Session Smart Conductor and Session Smart Router contain an OS command injection vulnerability that could allow a remote attacker to execute arbitrary commands as root via a specially crafted salt minion ID.
US federal agencies had to fix it by 2026-11-28.
What to do about it
- Find out whether you run the affected product. Check the product names and versions above against what your business uses, including firewalls, routers, plugins and servers your provider manages for you.
- Apply the vendor’s fix, or the workaround. Install the update from the product’s maker. If none exists yet, follow their temporary workaround or take the affected system off the public internet.
- Check for signs it was already used. Look for new admin accounts, unexpected files and unusual outgoing traffic. If the flaw is on the CISA exploited list, assume attackers have already tried it on exposed systems.
Where this came from and what it does not tell you
- Source type
- News feed excerpt. The headline and opening summary from the publisher’s own feed. We do not copy the article.
- First seen by Securlabs
- ; last updated
- Limits
- Our summary is only what the publisher put in its feed. The full story, with quotes and later corrections, is at the source.
View the raw record (JSON)
{
"id": "news_c0fdeca5bfd2c130",
"title": "CISA Adds 10 Known Exploited Vulnerabilities to Catalog",
"category": "cve",
"severity": "critical",
"status": "active",
"entity": "Cyber Incident",
"country_code": "US",
"summary": "CISA has added 10 new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog , based on evidence of active exploitation. CVE-2023-25914 Danfoss AK-SM 800A Series Path Traversal Vulnerability CVE-2023-25915 Danfoss AK-SM 800A Series Improper Input Validation Vulnerability CVE-2025-41450 Danfoss AK-SM 800A Series Improper Authentication Vulnerability CVE-2026-103406 Hewlett Packard ...",
"technical_details": "Source publication: CISA Cyber Advisories\nFeed URL: https://www.cisa.gov/cybersecurity-advisories/all.xml\nLink: https://www.cisa.gov/news-events/alerts/2026/11/25/cisa-adds-10-known-exploited-vulnerabilities-catalog\nPublished: 2026-11-25T12:00:00+00:00",
"source_name": "CISA Cyber Advisories",
"source_url": "https://www.cisa.gov/news-events/alerts/2026/11/25/cisa-adds-10-known-exploited-vulnerabilities-catalog",
"raw_data": "{\"tags\": [], \"author\": \"CISA\", \"guid\": \"/node/25859\"}",
"detected_at": "2026-11-25T12:00:00+00:00",
"resolved_at": null,
"updated_at": "2026-11-27T00:04:49.846752+00:00",
"image_url": null
}