Every incident in TCPShield's own record, newest first, with each update the provider posted. Durations are the provider's, from when it logged the incident to when it marked it resolved.
· lasted 1h 16m
Affected: Seoul
resolved ·
This incident has been resolved.
monitoring ·
The swap has been completed and all core services are back online. We are verifying state before shifting production traffic back over.
identified ·
At 16:44:20 UTC, our Seoul location experienced a transmit stall on the network card serving production traffic. Because of recurring issues with this NIC, we have arranged a hardware replacement with the datacenter, scheduled to begin at 03:00 KST with expected completion by 05:30 KST. Stateful traffic is being routed through Tokyo until the replacement is complete.
· lasted 9h 47m
Affected: Frankfurt (Anycast)
resolved ·
This incident has been resolved.
monitoring ·
We are continuing to monitor for any further issues.
monitoring ·
The affected node has been put back in rotation at approximately 03:30 UTC. A partial disconnect is expected in the process due to ECMP.
monitoring ·
A fix has been implemented and we are monitoring the results.
identified ·
From 18:17 to 18:19 UTC, a single node in our Frankfurt fleet experienced an OOM (ran out of memory). Some traffic routed through Frankfurt saw a brief disruption of about 2 minutes. Service automatically failed over to other nodes in the process, and all other locations were unaffected. We have identified the root cause and deployed a corrective fix. No further impact is expected, and no action is needed from end users.
· lasted 47 min
Affected: Tokyo
resolved ·
Traffic across all services in Tokyo has remained stable since the replacement. We are marking this incident as resolved.
monitoring ·
At approximately 03:55 UTC, we performed a hardware replacement at our Tokyo location to resolve a long-standing issue caused by faulty DRAM, which had been causing the affected server to crash roughly every 12 hours. The replacement was completed in about 45 minutes, and production traffic was shifted back onto the new hardware as of 04:45 UTC. We do not anticipate any further degradation or maintenance windows for Tokyo and will continue to monitor closely.
· lasted 1h 1m
Affected: Seoul
resolved ·
The spare optic has been enabled and traffic has been restored to the location as of 04:12 UTC. Traffic previously on Tokyo has moved back to Seoul.
investigating ·
Our Seoul location is currently experiencing an issue with its optical transceiver resulting in traffic loss. Traffic has been automatically diverted to Tokyo until this component is replaced. We will keep this status updated as it progresses.
· lasted 2h 15m
Affected: London, Singapore, Frankfurt (Anycast), Tokyo, Amsterdam
resolved ·
The previously reported latency increase has resolved as of 16:46 UTC following re-convergence on the backbone. We await root cause from the network team.
investigating ·
Cloudflare and OVH routes are unaffected. We will post a further update as soon as more information becomes available.
investigating ·
We are investigating an anomaly that occurred within the GSL backbone at 13:23 UTC. Traffic has since recovered after 1 minute, with minor residual latency of approximately 5ms.
· lasted 5 min
Affected: Ashburn, Sydney, Miami
resolved ·
A long running TCP flood caused connection state tables to fill in some locations, resulting in intermittent login and ping failures. The root cause of the excess state allocations has been identified and fully remediated as of 01:23 UTC. All regions are operating normally and we will continue to monitor closely. If you are still experiencing any issues, please open a support ticket and our staff will be happy to assist.
monitoring ·
A fix has been implemented and we are monitoring the results.
investigating ·
We are currently investigating elevated error rates in US East, US West, and AU, where some logins are failing to process. The root cause has been identified and we will post further updates as remediation progresses.
· lasted under a minute
Affected: Frankfurt (Anycast)
resolved ·
Between 07:43 and 07:46 UTC, our Frankfurt network experienced intermittent packet loss due to attack traffic leakage. The root cause was quickly identified as a single destination IP had been configured with a weaker mitigation profile, allowing a portion of attack volume to bypass filtering. The affected IP was reconfigured immediately. As a precaution, we also completed a full audit of all public-facing IPs to ensure consistent mitigation posture across the fleet. No further impact is expected.
· lasted 20h 44m
Affected: Tokyo
resolved ·
Following hardware replacement completed by our datacenter, service in Tokyo has been fully restored. All player traffic has been routed back to Tokyo as of July 7th, 14:00 UTC, and the location is operating normally. We thank you for your patience while replacement hardware was sourced and installed. データセンターによるハードウェア交換が完了し、東京拠点のサービスは完全に復旧いたしました。現在、すべてのトラフィックは東京経由で正常にルーティングされています。
investigating ·
At approximately 16:42 UTC, our Tokyo location experienced a suspected motherboard failure. The affected node is unresponsive to power on attempts following initial investigation. Players previously routed via Tokyo have automatically failed over to Seoul, and both tunnel + proxy services remain operational. We are working with the datacenter to diagnose the fault and arrange hardware replacement. Once the node is restored and validated, traffic will be returned to Tokyo. We will provide further updates as the datacenter investigation progresses.
· lasted 4h 42m
Affected: Sydney
resolved ·
This incident has been resolved.
monitoring ·
We are continuing to monitor for any further issues.
monitoring ·
We have received confirmation that connectivity to Sydney has been restored. Players who have failed over to other locations are now terminating again in Sydney.
identified ·
Traffic has automatically been re-routed to Singapore and Tokyo respectively, and should not be impacting logins at this time.
identified ·
We are currently aware of a disruption affecting Equinix SY5 (Sydney). The issue currently stems upstream and we will post updates once we know more.
· lasted under a minute
resolved ·
From 09:21 UTC to 09:43 UTC, the GSL network team performed routine maintenance on the scrubbing hardware in Frankfurt for the purpose of an OS upgrade + NIC swap. Normally, these procedures do not cause any form of traffic blackholing in other sites. Unfortunately for us, the way our statics are setup in Frankfurt, such procedures did cause a full blackhole in traffic for the duration of the maintenance. We've stressed to the team the importance of heads up in cases such as these, and informed them on the necessity on timing it closer to off peak windows. No further maintenance is required in Frankfurt at this time.
· lasted 3h 12m
Affected: Frankfurt (Anycast), Amsterdam
resolved ·
This incident has been resolved.
monitoring ·
We are continuing to monitor for any further issues.
monitoring ·
We are actively monitoring for repeat events (should they occur) since 18:30 UTC.
investigating ·
Due to a large and sophisticated zero-day attack targeting a customer in Europe, parts of EU observed degradation from between 18:21 to 18:25 UTC. From 18:30 UTC onwards, we managed to divert the volume away from Europe and fully eliminate impact towards the network.
· lasted 4h 18m
Affected: Amsterdam
resolved ·
This incident has been resolved.
monitoring ·
Since 12:59 UTC, we have observed intermittent logouts via our Amseterdam location as a result of very short lived route flaps observed on the backbone. These "flaps" (i.e. temporary route changes) cause TCP sessions to divert to another location for ~500ms. During this window, existing sessions can sometimes reset, as the session state is unknown. We have implemented a fix across all of Europe as of 20:30 UTC and monitoring results.
· lasted under a minute
resolved ·
At 19:42:10 UTC, our Amsterdam location experienced forwarding degradation lasting approximately 1 minute. The root cause is being investigated by GSL at this time, as the issue is external to our own infrastructure. We will share updates as we learn more, and will pull routing from Amsterdam to alternate locations in the event of a recurrence. In the meantime, we continue to monitor.
· lasted under a minute
resolved ·
From 19:41 to 20:12 UTC, all European locations experienced significant packet loss affecting all European backends. The root cause was backbone link saturation triggered by an attack targeting an adjacent customer on GSL's network, which caused spillover effects across our infrastructure and GSL's network more broadly. In response, the GSL team (myself included) has placed this customer into a preconfigured mitigation stance that will proactively block this traffic upon re-occurrence. We do not anticipate a repeat of this event.
· lasted 2h 13m
Affected: Ashburn
resolved ·
Login error rate has been restored and a corrective patch has been deployed, tested, and verified globally throughout the network. We continue to monitor and do not expect this issue to resurface. If you see any issues, please don't hesitate to reach out via ticket.
monitoring ·
We are continuing to monitor for any further issues.
monitoring ·
A fix has been implemented and we are monitoring the results.
identified ·
The issue has been identified and a fix is being implemented.
investigating ·
We are currently seeing elevated error rate for the US east region, where some logins are failing to process. We are investigating the root cause.
· lasted under a minute
Affected: Amsterdam
resolved ·
PSU replacement was successful. Traffic has re-converged and we will continue to monitor for anything unusual.
identified ·
At 17:35 UTC, a server in our Amsterdam location underwent an unexpected PSU related hardware failure. The device has underwent a remote hands procedure at 23:46 UTC and is expected to be back in production 3 hours from now. We will keep this updated as it progresses.
· lasted under a minute
resolved ·
At 17:35 UTC, a server in our Amsterdam location underwent an unexpected PSU related hardware failure. The device has underwent a remote hands procedure at 23:46 UTC and is expected to be back in production 3 hours from now. We will keep this updated as it progresses.
· lasted 19 min
Affected: Singapore
resolved ·
Routes have successfully reconverged, latency has also normalized.
monitoring ·
Singapore is recovering and routes are currently reconverging, will provide next update by 17:00 UTC.
investigating ·
Since 15:45 UTC, due to ongoing datacenter work at Equinix SG3, this location unexpectedly saw full downtime as a result of a core router being swapped in the rack. Our upstream (GSL) is engaged and routing converging routes to other nearby locations (Tokyo, Seoul) until the situation subsides.
· lasted 20 min
Affected: Singapore
resolved ·
The degradation has been resolved and continuing to monitor.
monitoring ·
We have applied a corrective fix for the NIC driver issue observed and are monitoring results.
investigating ·
Since 06:00 UTC we have observed performance degradation in Singapore, we are investigating. Root cause is not an attack.
· lasted under a minute
resolved ·
At around 1:48 UTC, our network globally received a series of sophisticated TCP attacks aiming to replicate legitimate traffic. These attacks were executed at high packet rate, peaking as high as 3Gpps (billion packets per second) measured from the borders. By 1:55 UTC, we understood the full scope of the bypassing nature of the attack. By 03:38 UTC, tests have been written to match the corresponding mitigation to the new attack vector. By 03:45 UTC, the patch has been deployed globally to the network. And finally, at 05:20 UTC, we received 2 hits of the same attack vector with no further impact to our network. We continue to record and monitor all network flows towards our border and remain available to act quickly should any additional attempts arise.
· lasted 17 min
Affected: Warsaw
resolved ·
Datacenter confirmed fault. Services restored as of 09:52 UTC.
investigating ·
A few hours following the upgrade, the location has lost power at 09:23 UTC. The datacenter has acknowledged the situation and is investigating. Until then, traffic remains re-routed via Frankfurt.
· lasted 21h 52m
Affected: Ashburn, Singapore, Tokyo
resolved ·
This incident has been resolved.
monitoring ·
Starting at 04:21 UTC until 04:42 UTC, our network faced partial degradation due to a new complex attack vector in the following sites: - Singapore - Tokyo - New York Mitigations were applied towards the new vector at 04:42 and can confirm this has subsided immediate impact. Development on automated mitigations began at 05:10 until 06:25, with simulated lab environment testing conducted at 06:45. Lab scenarios confirm the vector is automatically blocked and cannot cause further impact. We have rolled out the new mitigation code to the appliances in the impact sites and are monitoring results.
The provider writes these records, so a short incident may have been a longer problem for some customers. The longest resolved incident is the figure to plan around if TCPShield is in a path your customers use; the average is what a normal bad day looks like. Providers keep only recent history, so older incidents may have aged out of their feed rather than never having happened.