Occupancy monitoring via unencrypted RF communication
The static codes used for information transmission throughout the 433.92 MHz system of the Guardian 2 system allow an attacker in proximity to monitor the movements of users inside the premises where the sensors are set up. This is further aided by the fact that codes transmitted reveal sensor type, although sensor location cannot be inferred from this traffic alone.
Cleartext Transmission of Sensitive Information CWE-319
The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
Weakness data: MITRE Common Weakness Enumeration.
New to this? Read how to keep your software updated.
The products and versions NIST lists as vulnerable. If what you run is not listed it is probably not affected, but ask your provider if you are unsure.
| Product | Type | Vulnerable versions | Fixed in |
|---|---|---|---|
| Onyx Cookware ApS Nexsmart Guardian 2 (Alarm system) | Software | 0 | not recorded |
The 7.1 severity score (high) from the company that reported it, broken into what it means in practice. Red means it makes the flaw easier or worse.
| How it is reached | Nearby network | The attacker has to be on the same local network (office Wi-Fi or the same hosting network). |
| How hard it is | Low | Easy to carry out. No special conditions have to line up. |
| Setup needed on the target | None | No special setup on the target is needed. |
| Login needed | None | The attacker does not need an account or password. |
| Someone has to act | None | Nobody has to click or open anything. It can happen on its own. |
| Data exposed | High | Total loss of confidentiality: the attacker can read all the data the program can reach. |
| Data changed | None | Nothing can be changed. |
| Service disrupted | None | The service keeps running. |
NIST lists 1 sources for this flaw, none tagged as a vendor patch.